Fix pack 6 release notes
Fix pack 6 of IBM Tivoli Netcool Configuration Manager V6.4.2 is now available from IBM Fix Central at http://www.ibm.com/support/fixcentral/. Fix pack installation, fixes and known limitations are described here.
Enhancements and updates
- Golden configurations can be edited
-
Before this fix pack, golden configurations could not be edited. As of Fix Pack 6, configurations marked as golden can be edited, if they do not contain regular expressions.
For more information, see Managing golden configurations.
APAR fixes
Number | Title |
---|---|
IJ04975 |
NCM6.4.2.5 REST API post function does not work anymore For more information, see Configuring WebSphere Application Server for Network Service Manager. |
IJ04874 | ITNCN OOBC Email notifier function |
IJ01166 | Unable to use custom names for group names when using AD/LDAP authentication |
Limitations
The limitations documented in the release notes for previous fix packs of Netcool Configuration Manager still apply to this version, unless listed as fixed in a subsequent edition of the release notes.
Installing
To install the IBM Tivoli Netcool Configuration Manager Version 6.4.2 fix pack 6, you download the ITNCM repository for IBM Installation Manager and run the installer.
These instructions describe how to move from a previous minor version of V6.4.2, for example, V6.4.2.5, to the latest version, V6.4.2.6, by installing fix pack 6. Installing this fix pack on any other version is not supported. If you want to upgrade to V6.4.2 from a previous major version, for example, V6.4.1, you must do that before installing any fix packs.
For information about upgrading to the latest major version, refer to Upgrading Netcool Configuration Manager to version 6.4.2.0.
A number of requirements and restrictions apply to Linux on System z installations. See the Software requirements topic for more information.See the 'Software requirements' topic in the IBM Tivoli Netcool Configuration Manager Installation and Configuration Guide 'Planning' section for more information.
- Save any customized memory settings so that you can restore them after installing the fix pack.
-
Back up any files that you have modified, excluding the files in the following list. After upgrading, reapply your changes to the newly installed versions of the files that you backed up. The fix pack upgrade preserves changes to the files in the following list, therefore, you do not need back up these files, regardless of whether you have changed them. All files are within the Netcool Configuration Manager home directory.
bin/config.sh compliance/config/properties/AdminManager.properties compliance/config/properties/ComponentManager.properties compliance/config/properties/Event.properties compliance/config/properties/LoggingServer.properties compliance/config/properties/OOBChangeProcessor.properties compliance/config/properties/RMServer.properties compliance/config/properties/RemedialActionsManager.properties compliance/config/properties/WorkFlowManager.properties compliance/config/properties/jpa.properties compliance/config/properties/rseries.properties compliance/installer/CMServer.properties config/properties/.intelliden.properties config/properties/driver.properties config/properties/logger.properties config/properties/rseries.properties config/properties/vendor.properties config/properties/verifyPermissions.properties oobc/install/install.properties ITNCM.properties compliance/config/properties/PortManager.properties
- Note the JazzSM credentials of the user that restarts Netcool Configuration Manager on this server. Use these credentials when prompted for JazzSM credentials by the installation process.
-
Download the fix pack from Fix Central.
The following files are available for download. Netcool Configuration Manager is available only as a 64-bit version.Table 2. Netcool Configuration Manager fix pack files File Description ITNCM_Base_AIX_FPN.tar
ITNCM_Base_Linux.tar
ITNCM_Base_zLinux.tar
This fix pack of Netcool Configuration Manager Version 6.4.2 for AIX, Linux and zLinux, where
N
is the fix pack number.Also includes the ITNCM DashBoard Components.Note: The ITNCM DashBoard Components are only required when your system is integrated with Network Manager, and not for stand-alone Netcool Configuration Manager installations.oobc_AIX.zip
oobc_Linux.zip
oobc_zLinux.zip
Out of band change installers for AIX, Linux and zLinux - Uncompress the ITNCM_Base_AIX_FPN.tar file.
-
Quit all running programs. Stop all running instances of Netcool Configuration Manager by running the following command:
<install directory>/bin/itncm.sh stop
-
Log onto the Netcool Configuration Manager server.
You must install the fix pack on all presentation, worker and reporting servers.
-
Start IBM Installation Manager in either interactive or silent mode.
-
For interactive mode, change to the /eclipse/ subdirectory of the IBM Installation Manager group installation directory and use the following command to start IBM Installation Manager:
./IBMIM
-
To record the installation steps in interactive mode in a response file for use with silent installations on other computers, use the
-record response_file
option. For example:IBMIM -record C:\response_files\install_1.xml
-
For silent mode, change to the /eclipse/tools/ subdirectory of the IBM Installation Manager group installation directory and use the following command to start IBM Installation Manager:
imcl -c
-
- If necessary, configure proxy settings and enable IBM Installation Manager to be able to download package repositories from IBM Passport Advantage. These options are in the Internet and Passport Advantage sections of the Preferences menu.
- Add the downloaded fix pack file as a repository to IBM Installation Manager, in .
-
In the main Installation Manager menu, click Update, and then select Netcool Configuration Manager.
Follow the instructions to complete the installation.
Important: Do not deselect any components that are already selected. Deselecting components uninstalls them. - Accept the license agreement and select an installation directory.
-
In an interactive installation, supply the following details:
- Netcool Configuration Manager database details
- Sid/service name/database name(db2)
- DASH administrative credentials
- DASH administrator
username. Important: Do not accept the default username of
smadmin
. Your installation might continue, but fail later. Use the DASH credentials that were originally used when Netcool Configuration Manager was installed. The default username wasIntelliden
. - Network Manager administrative credentials
- Default is either itnmadmin or the DASH superuser, who must have the
ncw_admin
role in DASH - Netcool Configuration Manager presentation server
- Connection details to the Netcool Configuration Manager Presentation server.
- Tivoli Common Reporting server
- Connection details to the Tivoli Common Reporting server
- Complete the update.
- Install the fix pack on all other presentation, worker and reporting servers.
If you encounter any errors during the installation, refer to the following information: Troubleshooting installation.
- Clear the browser cache
- After upgrading, clear the cache on any browsers that you use to work with Netcool Configuration Manager.
- Upgrade database schema
- Upgrade the database schema to the latest version on the main presentation server only, by
running the following
command:
Where version is the current version of the product that you are upgrading from. For example:install_dir/bin/utils/database/upgrade/upgradeDBSchema.sh version
To verify the current version, run the following command:/opt/IBM/tivoli/netcool/ncm/bin/utils/database/upgrade/upgradeDBSchema.sh 6.4.2.5
In the following example output, the version is 6.4.2.5:cat <install_dir>/config/rseries_version.txt
6.4.2.5-27052019062220-01-f8a8c49b816
- Update Netcool Configuration Manager DASH components
- If your system is integrated with Network Manager, you must also update the Netcool Configuration Manager DASH components on the Network Manager GUI server
- Configure Alerts menu of the Active Events List (AEL)
- If your system is integrated with Network Manager, you must again add access to the Activity Viewer from the Tivoli Netcool/OMNIbus Active Event List by configuring the Alerts menu.
- Reapply any previous memory settings
- Customized memory settings are not preserved during upgrade, and you must update them manually after the upgrade.