Fix pack 3 release notes
IBM Tivoli Netcool Configuration Manager V6.4.2 fix pack 3 is available. Fix pack installation, fixes and known limitations are described here.
Enhancements and updates
- Supported software updates
- Operating system, database and browser support has been extended to the latest versions.
- Golden Configuration Regular expression enhancements for non-textual fields
- For Alcatel and Cisco devices, the golden configuration regular expression syntax has been enhanced to support it's use in non textual fields of a configuration.
Documentation Apar changes
- alm00323162 / IV86059
- A topic documenting the WebSphere security configuration backup process is no longer needed in version 642 of Netcool Configuration Manager, and has been removed.
- alm00323921 / IV89313: ITNCM Rest/NSM API documentation corrections
- The name for the service template ID has changed from 'id' to 'serviceTemplateid'.
Installing
To install the IBM Tivoli Netcool Configuration Manager Version 6.4.2 fix pack 3, you download the ITNCM Installation Manager repository.
File | Description |
---|---|
ITNCM_Base_AIX.tar ITNCM_Base_Linux.tar ITNCM_Base_zLinux.tar |
Netcool Configuration Manager Version 6.4.2 fix pack 3 for AIX, Linux and zLinux Also includes the ITNCM DashBoard Components.
Note: The ITNCM DashBoard Components are only
required when your system is integrated with Network Manager, and not for stand-alone
Netcool Configuration
Manager
installations.
Restriction:
Netcool Configuration Manager Version 6.4.2 fix pack 3 and fix pack 4 can only be deployed on Linux on System z as a stand-alone solution deployed on a worker server. Deployments that include Tivoli Common Reporting or the use of the DASH portlets are not supported on zLinux. Netcool Configuration Manager Version 6.4.2 fix pack 4 allows the use of Cognos Analytics to view ITNCM Reports on zLinux platforms. Such installations are, however, limited to single-server, stand-alone deployments, with no integration or use of the DASH portlets. |
oobc_AIX.zip oobc_Linux.zip oobc_zLinux.zip |
Out of band change installers for AIX, Linux and zLinux |
- This fix pack needs to be executed on all presentation, worker and reporting servers.
- Quit all programs before continuing with the upgrade.
- Customized memory settings are not preserved during upgrade, and therefore must be updated manually after the upgrade.
- When validating the JazzSM credentials, remember that the user is the same one used to restart Netcool Configuration Manager on this server.
- Log onto the Netcool Configuration Manager presentation server.
-
Change to the /eclipse subdirectory of the Installation Manager Group installation directory and use the following command to start Installation Manager:
To record the installation steps in a response file for use with silent installations on other computers, use the./IBMIM
-record response_file
option. For example:IBMIM -record C:\response_files\install_1.xml
-
Configure Installation Manager to download package repositories from IBM Passport Advantage:
-
From the main menu, choose
.Tip: You can set preferences for proxy servers in IBM Installation Manager. Proxy servers enable connections to remote servers from behind a firewall. -
In the Preferences window, expand the Internet node and select one of the following options:
- FTP Proxy
- Select this option to specify a SOCKS proxy host address and a SOCKS proxy port number.
- HTTP Proxy
- Select this option to enable an HTTP or SOCKS proxy.
- Select Enable proxy server.
- In the Preferences window, select the Passport Advantage panel.
- Select Connect to Passport Advantage.
- Click Apply, and then click OK.
-
-
In the main Installation Manager window, click Update, and then select Netcool Configuration Manager. Follow the installation wizard instructions to complete the installation.
-
Accept the license agreement, select an installation directory, and supply the following details:
- Netcool Configuration Manager database details
- Sid/service name/database name(db2)
- DASH administrative credentials
- DASH administrator
username. Important: Do not accept the default username of
smadmin
. Your installation might continue, but fail later. Use the DASH credentials that were originally used when Netcool Configuration Manager was installed. The default username wasIntelliden
. - Network Manager administrative credentials
- Default is either itnmadmin or the DASH superuser, who must have the
ncw_admin
role in DASH - Netcool Configuration Manager presentation server
- Connection details to the Netcool Configuration Manager Presentation server.
- Tivoli Common Reporting server
- Connection details to the Tivoli Common Reporting server
- Complete the update.
- Clear the browser cache
- After upgrading, clear the cache on any browsers that you use to work with Netcool Configuration Manager.
- Upgrade database schema
- Upgrade the database schema to the latest version on the main presentation server only, by
running the following
command:
Where version is the current version of the product that you are upgrading from. For example:install_dir/bin/utils/database/upgrade/upgradeDBSchema.sh version
To verify the current version, run the following command:/opt/IBM/tivoli/netcool/ncm/bin/utils/database/upgrade/upgradeDBSchema.sh 6.4.2.5
In the following example output, the version is 6.4.2.5:cat <install_dir>/config/rseries_version.txt
6.4.2.5-27052019062220-01-f8a8c49b816
- Update Netcool Configuration Manager DASH components
- If your system is integrated with Network Manager, you must also update the Netcool Configuration Manager DASH components on the Network Manager GUI server
- Configure Alerts menu of the Active Events List (AEL)
- If your system is integrated with Network Manager, you must again add access to the Activity Viewer from the Tivoli Netcool/OMNIbus Active Event List by configuring the Alerts menu.
- Reapply any previous memory settings
- Customized memory settings are not preserved during upgrade, and you must update them manually after the upgrade.
APAR fixes
ALM | APAR | Description |
---|---|---|
00323144 | IV85980 | Compliance slow performance on fetching data; it is taking up to 10 seconds when expanding a realm under Policy Definitions or under Execution |
00323162 | IV86059 | PLEASE REMOVE UNNECESSARY PAGE FROM ITNCM 6.4.2 ONLINE DOCUMENTATION - Backing up and restoring WebSphere security configuration is no longer used in 642 |
00323921 | IV89313 | ITNCM REST/NSM API DOCUMENTATION CORRECTIONS. |
00323900 | IV89605 | UNABLE TO LOCATE RESPECTIVE OS REGISTRY WHEN CREATING OS SPECIFICATION |
Limitations
Activity ID | Area | Description | Workaround |
---|---|---|---|
6213 | ITNCM Core | Applying a Search Set without an XPath marks the UOW as a success | Insert a valid XPath in the Search Set to avoid a false UOW status being returned |
6211 | Compliance | The view/edit parameters are not working properly when executing a compliance policy (need to select back button) . | User can select "Back" button followed by "Next" |
6147 | Uninstalling | iso-swid directory is not removed when ncm is uninstalled | Delete the directory manually |
5030 | TCR Reports | Executing the Policy Compliance Score and Summary Report from NM Network view shows incorrect data in the bar chart. | Run the report from the standalone TCR reports. |
4139 | Installation | Erroneous errors are generated by Install Manager during a CLI installation. The errors are related to numbering the CLI options. | No work around needed, as the errors have no impact on the installation. |
4749 | TCR Reports | An extra line is generated at the bottom of the report | none |
5139 | Integration | NcKL rules have a typo preventing the MTTrapd probe from starting after their application. | An up to date version will be available from fix Central to download and use. |
4440 | ITNCM Core | When running the configuration archive utility, scoping by date units may result in some configurations on the same day not being included for archiving. | Run the utility again on the following day. To ensure consistent results, run the utility at the same time each day. |
5759 | Compliance |
PolicyExport.sh/PolicyImport.sh will not work for Golden Config Role Based Compliance The tools effectively export and import a set of policy/ rule/ definition/ evaluation based tables, prior to golden config the columns did not contain internal id values (except for realm which is regenerated on import. For golden config a column was added to the definition table with the resource id of the golden config device. |
No workaround |
5691 | Upgrading |
Customised smtp server is being overwritten and set to default when upgrading The initial smtp server set in IM is not updated during an update and reverts to the initial value set during the initial install. |
Update smtp server after Update |
5662 | NCM Dash Components |
NCM Dash Components error on upgrade When “Save files for Rollback” is not selected during the initial install (selected by default in IM File -> Preferences -> Files for Rollback) an error will occur during the update/uninstall process. |
Uninstall the NCM Dash Components and install the new version this time ensuring Save files for rollback is installed to allow for easier updates in future. |
5651 | Compliance |
Recurring Schedule always shows unscheduled when selecting edit the process schedule The Oracle JRE does not ship Xalan and this causes an error to occur on checking schedules through the local client. |
Install Xalan locally on your machine to resolve the issue. |
5796 | ITNCM Core | openjpa exceptions in the Server.err log on a standalone worker server | None, as this only affects the product on shut-down and does not impact functionality. |
5909 | ITNCM Core | User is able to dequeue a UOW without Manage Work Privilege | none |
5908 | Integration | Policy Traps do not clear automatically from the AEL on NM when the policy is rerun and compliant the second time | Manually clear the original fault trap when the Clear trap is received |
5881 | Integration | Device Activity Viewer doesn't work from Policy Traps when launched from the AEL on NM | Run the Device Activity Viewer for the node in question from a Network View (including Hop View/Fault Finding View/Network Health View/Path View) or other alarm types raised on behalf of the same device (eg Configuration change alarms) |
5864 | Integration | NCM DASH components : NM wizards : custom labels are not getting picked up | The wizard will execute successfully without a label. Alternatively if required, a label can be inserted if the Unit Of Work is run from the native NCM GUI. |
5856 | Integration | NCM DASH components : Apply Policy from NM wizard: cannot view/edit global parameter | If the global parameter needs to be changed, run the policy from the native NCM compliance GUI |