Configuring the discovery profile

You can use the following options to configure the zEnterprise® sensor discovery.

Port sensor configuration

You must add the ECC port to the Portlist option of the Port sensor configuration and specify it in the enterpriseCCPortList option. The enterpriseCCPortList option is used to establish which port that is listed in the Portlist is the one that the ECC listens on. The sensor uses this option also to establish the list of ports that are subject to additional actions, such as execution of the zEnterprise sensor. The same list of ports must be specified in the portList option for the sensor to run.

ZEnterprise sensor configuration

You can use this configuration to extend timeout and retry counts to tune the connection to the ECC, or to change any URL for queries if any alterations of those queries are made in the future ECC versions.

If you want to capture the entire zEnterprise landscape, you can set the storeUnknownComputerSystems flag to true. This parameter forces the sensor to store a computer system of an unknown type or the one without proper identification set.