show sensors-other
This command displays the status of sensors that have true or false values.
Syntax
show sensors-other
Availability
Physical appliances only.
Guidelines
The show sensors-other command provides the state of sensors that have true or false (nonnumeric) values.
Which sensors the appliance provides depends on the
appliance. The following list includes the sensors that different
appliance provide, but the sensors are not limited to the ones in
the list.
- Battery status
- Intrusion detection
- Hard disk drive status
- RAID controller status
- Power supply status, including failures, lack of input power, and so forth
- DRAM memory status
- PCI bus status
- CPU status
The output for the show sensors-other command
includes the following data.
- The name of the sensor that is being monitored. The name is in
the form of a descriptive predicate. If the value of the sensor is
true
, the descriptive predicate istrue
; if the value of the sensor isfalse
, the descriptive predicate isfalse
. For example, the sensor nameIntrusion detected
with a value offalse
means that intrusion is not detected. - The value of the sensor. The value is either true or false.
- The status of the sensor. The status can be one of the following
values.
- OK
- The reading of the sensor is normal.
- Failure
- The reading of the sensor indicates a problem or a failure in the appliance.
- No reading
- No reading of the sensor is available now. An internal hardware or software error might occur. Contact IBM® Support.
- Invalid
- The DataPower® software requested a sensor reading by using an invalid sensor identifier. An internal DataPower software error might occur. Contact IBM Support.