show sensors-other

This command displays the status of sensors that have true or false values.

Syntax

show sensors-other

Availability

Physical appliances only.

Guidelines

The show sensors-other command provides the state of sensors that have true or false (nonnumeric) values.

Which sensors the appliance provides depends on the appliance. The following list includes the sensors that different appliance provide, but the sensors are not limited to the ones in the list.
  • Battery status
  • Intrusion detection
  • Hard disk drive status
  • RAID controller status
  • Power supply status, including failures, lack of input power, and so forth
  • DRAM memory status
  • PCI bus status
  • CPU status
The output for the show sensors-other command includes the following data.
  • The name of the sensor that is being monitored. The name is in the form of a descriptive predicate. If the value of the sensor is true, the descriptive predicate is true; if the value of the sensor is false, the descriptive predicate is false. For example, the sensor name Intrusion detected with a value of false means that intrusion is not detected.
  • The value of the sensor. The value is either true or false.
  • The status of the sensor. The status can be one of the following values.
    OK
    The reading of the sensor is normal.
    Failure
    The reading of the sensor indicates a problem or a failure in the appliance.
    No reading
    No reading of the sensor is available now. An internal hardware or software error might occur. Contact IBM® Support.
    Invalid
    The DataPower® software requested a sensor reading by using an invalid sensor identifier. An internal DataPower software error might occur. Contact IBM Support.