You must manually enable the Add/Modify Linear Referencing Methods
menu option in the Security Groups application. You can also enable several other license-based
components at the same time.
Procedure
- In the Security Groups application, specify EVERYONE in
the Group field and then click the Applications tab.
- Select the Assets application.
- In the Options for Assets table, select the Grant Access check box
for the Add/Modify Linear Referencing Method option.
- Ensure that the check boxes to grant access to the Add/Modify
Conversions and the Add/Modify Units of Measure options are also selected.
These menu options must be enabled because you must configure
units of measure and conversion factors to use in your linear referencing
methods.
- Filter for the following options and grant access to them
also:
- Filter by Linear Assets
- Relationships tab
- View Relationship History
- Click Grant Listed Options for this Application to commit the
changes that you configured.
What to do next
Use the same procedures to grant access to the Filter
for Linear Assets option in the following applications:
- Work Order Tracking
- Service Requests
- Quick Reporting
- Preventive Maintenance