Setting up and tuning the SUT

This topic describes the multiple ECM node clustered setup of the SUT. The Part 1 white paper described a single ECM node setup. This Part 2 white paper of the case study describes a clustered setup with WAS and Spectrum Scale.

The setup and tuning applied to the SUT was described in detail in the Part 1 white paper. Since the Part 2 white paper uses the same basic tuning that was used for Part 1, you should refer to the Part 1 white paper IBM Enterprise Content Management for Linux on z Systems, Scale-Out Case Study (Part 1): Single ECM Node with XFS and IBM Spectrum Scale 4.2 for details.

The setup tuning covered these main programs:
  • z/VM
  • Linux for z Systems
  • WebSphere Application Server
  • ECM software components
  • DB2
  • Spectrum Scale
Table 1 lists the components that were tuned.
Table 1. Setup tuning used for Part 1 and Part 2 white papers
Program Components that were tuned
z/VM
  • Virtual Networking
  • HyperPAV
Linux on z Systems
  • Networking
  • HyperPAV
  • FCP Hardware Data Router Support
  • Device Mapper-Multipathing
  • Linux kernel parameter
ECM software tuning
  • IHS gateway tuning
  • common WAS tuning
  • WAS JVM tuning
  • ECM database server tuning
ECM database server
  • workload type
  • database configuration
  • database indexes
Spectrum Scale
  • pagepool size
  • maxFilesToCache
  • maxStatCache
  • blocksize