Example: Adapter report

The first example shows the output of the adapter report. This is the default report.

The adapter report shows important information about the currently attached FCP devices.

# ziorep_config

Host:    host0
CHPID:   36
Adapter: 0.0.3c07
Sub-Ch.: 0.0.0010
Name:    0x5005076401a07163
P-Name:  0x5005076401a07163
Version: 0x0003
LIC:     0x0000c74c
Type:    NPort (fabric via point-to-point)
Speed:   2 Gbit
State:   Online

Host:    host1
CHPID:   37
Adapter: 0.0.3d07
Sub-Ch.: 0.0.0011
Name:    0x5005076401e07163
P-Name:  0x5005076401e07163
Version: 0x0003
LIC:     0x0000c74c
Type:    NPort (fabric via point-to-point)
Speed:   2 Gbit
State:   Online
The fields of the report are described in Table 1.
Table 1. Report fields and their meanings
Field Meaning
Host: SCSI host ID, see the lsscsi command.
CHPID: Channel path ID.
Adapter: Device bus ID of the FCP device.
Sub-Ch.: ID of the I/O subchannel.
Name: The current WWPN of the FCP device.
P-Name: The permanent WWPN of the FCP channel.
Version: Version information for the FCP channel.
LIC: Licensed internal code, microcode version.
Type: Current connection type
Speed: Current connection speed
State: Current FCP device status (online or offline).