cio.d25039 Link stopped: RS=<reporting source> RSID=<reporting source ID> IC=<incident code> IUPARAMS=<incident unit parameters> IUNODEID=<incident unit node ID> AUPARAMS=<attached unit parameters> AUNODEID=<attached unit node ID>

Explanation

A hardware error has occurred. A unit at one end of an interface link has detected a failure in the link or in one of the units attached to the link. As a result, data transfer across the link has stopped. In the message text, the node IDs of involved units are represented in the following format: TTTTTT/MDL,MMM.PPSSSSSSSSSSSS,XXXX where TTTTTT refers to the machine type, MDL the model number, MMM the manufacturer, PP the manufacturing plant, SSSSSSSSSSSS the unit sequence number and XXXX the machine type-dependent physical interface number. If no data is available for the unit parameters or node ID field, "n/a" is used instead.

User response

Report the problem to your support organization.

Severity

Error