Example: Adapter report
The first example shows the output of the adapter report. This is the default report.
The adapter report shows important information about the currently attached FCP devices.
# ziorep_config Host: host0 CHPID: 36 Adapter: 0.0.3c07 Sub-Ch.: 0.0.0010 Name: 0x5005076401a07163 P-Name: 0x5005076401a07163 Version: 0x0003 LIC: 0x0000c74c Type: NPort (fabric via point-to-point) Speed: 2 Gbit State: Online Host: host1 CHPID: 37 Adapter: 0.0.3d07 Sub-Ch.: 0.0.0011 Name: 0x5005076401e07163 P-Name: 0x5005076401e07163 Version: 0x0003 LIC: 0x0000c74c Type: NPort (fabric via point-to-point) Speed: 2 Gbit State: Online
The fields of the report are described in Table 1.
| Field | Meaning |
|---|---|
| Host: | SCSI host ID, see the lsscsi command. |
| CHPID: | Channel path ID. |
| Adapter: | Device bus ID of the FCP device. |
| Sub-Ch.: | ID of the I/O subchannel. |
| Name: | The current WWPN of the FCP device. |
| P-Name: | The permanent WWPN of the FCP channel. |
| Version: | Version information for the FCP channel. |
| LIC: | Licensed internal code, microcode version. |
| Type: | Current connection type |
| Speed: | Current connection speed |
| State: | Current FCP device status (online or offline). |