HBO5017A The System Data Engine tried to gather SMF data from the 2G area of above-the-bar storage, but it did not find the vector table that points to this storage.
Explanation
An internal error prevented the System Data Engine from accessing the vector table anchor in the extended communication vector table (ECVT). The ECVT is accessed when the SDE is configured to collect data from the SMF user exit. This error prevents the SDE from collecting SMF data written to the high virtual storage by the user exit. SMF data written to SYS1.MANx is unaffected.
The SDE is unable to process data from the SMF exit.
Response
Verify that the SMF user exit HBOSMFEX is installed and active on the system where the SDE is running. Check the active SMFPRMxx in SYS1.PARMLIB to confirm that SMF data collection is active and that the user exit is defined. At least one SMF record must be written to the high virtual storage area to complete exit initialization. If the problem persists, contact IBM® Software Support.