Missing data or configuration errors after you upgrade to IBM Z APM Connect
After you upgrade to IBM Z® APM Connect, data is missing from a subscriber or other configuration errors occur.
Symptom
One of the following sets of symptoms is present:
- Log files are not received at the subscriber.
- Duplicate or obsolete data streams are in the Configuration Tool.
- Missing definitions for SMF data.
- Missing selections for log files.
Cause
The cause might be one of the following problems:
- Obsolete Configuration Tool files
- An old configuration tool plug-in
- Incorrect data set names
Solution
Complete the following steps:
- Ensure that the z/OSMF Configuration Tool plug-in is migrated to the V5R1 version. If the
plug-in is an old version, refer to the topics below to remove the plug-in and import the V5R1
plug-in.
Note: This is not applicable if you use the Liberty server Configuration Tool.
- Check the Configuration Tool working directory for files ending in
'
streams.json
' and ensure that old ones are deleted. In general, delete anystreams.json
file beginning withGLA*
that does not contain custom data. Ensure that the working directory contains the IBM suppliedstreams.json
file. The default installation location for the files is /usr/lpp/IBM/zoa/v5r1m0/zcdp/ZLDA,- cdp-starter-sets.streams.json
- dcollect.streams.json
- ims.streams.json
- log-forwarder.streams.json
- sde.streams.json
- zlda.enable.json
- zlda.protocols.json
- zlda.streams.json
- Check the data sets specified in System Data Engine configuration and ensure that they contain the V5R1M0 SMF definitions.