DFS2133 RESPONSE PTERM NOT INPUT PTERM I: sss1/name1, D: sss2/name2

Explanation

An application program inserted a message to an alternate response PCB specifying SAMETRM=YES. However, the logical terminal name2 does not point to the same physical terminal as name1.

In the message text:
sss1/name1
The source SYSID and source LTERM name for the input system.
sss2/name2
The destination SYSID and destination LTERM or TRAN code of the processing system.

System action

IMS logs the message in error, using log record type "64", and removes the message from the system.

Operator response

The error message sent to the input and the master terminals indicates the logical terminals involved. Check the logical terminal-to-physical terminal assignments. If correct, check the application program that produced the response. Inform the system programmer.

System programmer response

Correct the erroneous system definition application program, if required. Correct the logical-to-physical terminal assignments, if required.

Problem determination

14