DFS2061I NODE NOT AVAILABLE FOR OPNDST NODE x (USER y).
Explanation
An unavailable condition was returned on a VTAM® SIMLOGON issued due to an IMS /OPNDST command for NODE x or USER y. See VTAM For MVS/ESA, VM/ESA, VSE/ESA Programming (SC31-6496) and VTAM Messages and Codes (SC31-6418) for an explanation of this condition.
System action
The attempt to establish a session with NODE x or USER y has been terminated. (1) An IMS trace log record (X'67') containing pertinent information was produced with an ID of CVCT. (2) An IDC0 trace table entry is created, if the IDC0 trace is active. (For nonexisting dynamic terminals).
Operator response
See Programmer response.Programmer response
When the problem is corrected, session initiation can be attempted again using an IMS /OPNDST command. The session can also be requested or initiated by NODE x or USER y.