IEADMCxx example for IMS

This example shows creating a SYS1.PARMLIB member called IEADMCI1. DUMP parameters are given.

Create a SYS1.PARMLIB member called IEADMCI1 containing the following DUMP parameters:
JOBNAME=(j1,j2,j3,j4),SDATA=(CSA,PSA,RGN,SQA,SUM,TRT,GRSQ)
Where:
j1
IMS Control region job name.
j2
IMS DL/I region job name.
j3
DBRC region job name.
j4
IRLM region job name.
Create a second SYS1.PARMLIB member called IEADMCI2 containing the following DUMP parameters:
JOBNAME=(j5,j6,j7),SDATA=(CSA,PSA,RGN,SQA,SUM,TRT)
Where:
j5
IMS CCTL region 1.
j6
IMS CCTL region 2.
j7
IMS CCTL region 3.