DFS7417I INSTANCE yydddhhmmssth OF GSAM DBD|PSB name NOT HELD FOR DIRECTORY IMPORT. IT IS ALREADY IN THE IMS DIRECTORY

Explanation

The IMS Catalog directory already contains an existing GSAM member name with timestamp yydddhhmmssth, so the GSAM member name with the same timestamp was not copied to the IMS Catalog directory staging data set as a replacement for the directory member.

In the message text:
name
The GSAM member name.
yydddhhmmssth

The timestamp of the GSAM member that is already in the IMS catalog directory.

yydddhhmmssth represents the timestamp in the format of yy for year, ddd for day, hh for hour, mm for minutes, ss for seconds, and th for thousands of a second.

System action

Execution of the IMS Catalog Populate utility continues.

System programmer response

No action is required. However, to suppress this and other similar informational messages, specify NODUPLIST in the input control statements for the IMS Catalog Populate utility in a data set that is referenced by the ddname SYSINP.

Module

DFS3DU10