DFS0526A AN INCONSISTENCY EXISTS BETWEEN THE PSB AND THE DEDB'S DBD. PCB x IN PSB y. RGN n

Explanation

The DBD was changed in the DBDLIB and was used for an ACBGEN to build a PSB. A warning message was issued during ACBGEN that the DBD was not replaced in the ACBLIB.

System action

Abend code 1013 is returned to the CCTL to indicate a schedule request failure.

Programmer response

Rerun the ACBGEN utility to correct the inconsistency between the PSB and the DBD.

Module

DBFCPY00