DFS4752I READING DBD MEMBERS FROM IMS xxxxxxx DIRECTORY.

Explanation

This message indicates that the utility that is called is reading DBDs from the IMS catalog or staging directory instead of from the DBD, PSB, or ACB libraries.

This only occurs when ACBMGMT=CATALOG is specified in either the DFSDFxxx PROCLIB member or equivalent DFS3CDX0 user exit to enable IMS managed ACBs.

In the message text, the variable has the following meaning:

xxxxxxx
Indicates the directory from which the DBD resource is being read. Possible values include:
  • CATALOG
  • STAGING
Note: The DBD resource will only be read from the STAGING directory when ACBMGMT=CATALOG, and the STAGING keyword has been specified in the SYSIN DD card.

System action

The utility continues to process the requested function.

System programmer response

No action is required.

Module

DFSPCC30, DFSUCCT0