DFS4634I THE DEDB ALTER COPY BLK PROCESS WAS CLEANED UP DURING RESTART DEDB=dddddddd MODULE=aaaaaaaa

Explanation

During IMS restart, IMS detected that the DEDB Alter utility was running when IMS abnormally terminated. The ACTIVE ACBLIB contained an encrypted member, which IMS was able to delete.

System action

Emergency restart continues.

System programmer response

No action is required.

Module

DBFEDA00