DFS4160E ACBSHR=N IS SPECIFIED, BUT THE DIRECTORY IS SHARED BY OTHER IMS SYSTEMS.
Explanation
This IMS system is referencing an IMS catalog that is shared by other IMS systems, but this IMS
system cannot share the IMS catalog because ACBSHR=N
is specified in a PROCLIB
member that this IMS system uses. When the IMS management of
application control blocks (ACBs) is enabled, ACBSHR=N
indicates that the IMS catalog and the ACBs in the IMS directory data set are not
shared.
The ACBSHR=N
can be specified in either the DFSCGxxx member
or the COMMON_SERVICE_LAYER section of the DFSDFxxx member of the PROCLIB data
set.
Either the ACBSHR specification of the IMS system is incorrect, the IMS system is referencing the wrong IMS catalog, or the IMS catalog was set up by an IMS system that specified ACBSHR=Y.
System action
IMS terminates with abend U0071.
Operator response
Check that the specification of the ACBSHR and ALIAS parameters for this IMS are correct.
ACBSHR=Y
in
the appropriate PROCLIB member. The ACBSHR parameter can be specified
in the following locations:
If the IMS system is referencing the wrong IMS catalog, correct the specification of the ALIAS= parameter in the CATALOG section of the DFSDFxxx member. If necessary, run one of the IMS Catalog population utilities to load the ACBs that are required by this IMS system into the IMS catalog and its associated IMS directory data sets.
If the ACBSHR and ALIAS specifications for the IMS system are correct, the IMS catalog must be re-created to set it up as a non-shared IMS catalog.