DFS385A WORK AREA EXCEEDED IN FIELD name FOR REQUEST nnnn

Explanation

The Utility Control Facility was processing a request from the DFSYSIN data set when the field name in the DFSUCP70 work area overflowed.

System action

Processing terminates with a nonzero return code.

Programmer response

Too many parameters were specified on the control request nnnn. Make multiple control requests to do the same function as the one in error. This action shortens the overall length of the table requirements and still perform the required function. Resubmit the job; do not perform a RESTART.

Problem determination

2, 3, 8, 36. Also, if running under the Utility Control Facility, rerun the job with a FUNCTION=OP,MSGNUM=385 control statement in the DFSYSIN data set. Supply a SYSUDUMP DD statement to this step.

Module

DFSUCP40