DFS814I INITIALIZATION FAILED FOR FOLLOWING LINEGROUPS

Explanation

While initializing the line groups for the communications facility of IMS, IMS found that one or more line groups could not be initialized. A message listing the ddnames of the line groups involved and the reason they could not be initialized follows this message. Possible reasons for unsuccessful initialization include:
ddname
Reason
ddname.ALLOC
An incorrect device type has been allocated to this DD statement When the ddname is for a spool device, JES SPOOL DATASET (SYSOUT) might be incorrectly specified for at least one DD statement in the line group. This message is issued once for each DD statement in the line group, even if only one DD statement has an incorrect specification.
ddname.DUMMY
The first statement in a line group was specified as DD DUMMY.
ddname.NOFND
The DD statement was not present.
ddname.NOTSP
IMS-issued I/O operations do not support PDSW, HFS, or any other extended-format data sets.
ddname.STORG
There is not enough storage in subpool 0 to initialize the EXCP process.
ddname.UNIT
The DD statement does not point to a valid CTC device.

Operator response

(master terminal) Ensure that those line groups not initialized were intentionally not initialized. If line groups which should have been initialized were not, bring this message to the attention of the system programmer responsible for IMS.

Module

DFSIINB0