DFS0744A IMS HOLDS AN INDOUBT UOR FOR WHICH RRS HAS NO DATA:
URID=xxxxxxxxxx, TOKEN=yyyyyyyyyy

Explanation

During a restart, IMS determined that it held an indoubt unit of recovery (UOR), as identified by the IMS recovery token and the RRS unit of recovery identifier. However, z/OS® Resource Recovery Services indicated that hardened log data was unavailable. This data was needed to resolve the indoubt UOR.

In the message text:
xxxxxxxxxx
The RRS URID
yyyyyyyyyy
The IMS recovery token

System action

IMS builds a recoverable indoubt structure (RIS) for each indoubt UOR and waits for a resolution with the /CHA UOR command. The RIS is maintained until the UOR is resolved or a cold start is done. A cold start is not recommended.

User response

Resolve the indoubt UOR by issuing the /CHA command.

Module

DFSDRIS0