Receiving DFS3649A, the signon required message
The ETO user must sign on before a session can enter transactions or commands.
The user can enter the /RCLSDST command only
before signing on. IMS issues
message DFS3649A (indicating that a /SIGN command
is required) in each of the following situations:
- After a signon failure
- After a signoff
- After a logon in which no user data is entered
Any terminal user can then issue a /SIGN ON command to begin the next session.
You do not receive the DFS3649A message in any of the following
situations:
- Signon data is included in the VTAM® CINIT or BIND.
- The session is an ISC, SLU-P, Finance, or 3270 printer session.
- The terminal is a SLU-1 terminal running in unattended mode.
- The terminal is the subject of an autologon attempt.