Relationship of calls to PCB types
The following table shows the relationship of DL/I calls to I/O and alternate program communication blocks (PCBs).
The PCB can be specified as a parameter in the call list, or in the AIB, depending on which xxxTDLI interface is used:
Call | I/O PCBs | ALT PCBs |
---|---|---|
APSB 1 | ||
AUTH | X | |
CHKP (basic) | X | |
CHKP (symbolic) | X | |
CHNG 2 | X | |
CMD | X | |
DPSB 1 | ||
GCMD | X | |
GN | X | |
GSCD | X | |
GU | X | |
INIT | X | |
INQY | X | X |
ISRT | X | X |
LOG | X | |
PURG | X | X |
ROLB | X | |
ROLS | X | |
ROLL 1 | ||
SETO | X | X |
SETS | X | |
SETU | X | |
SYNC | X | |
XRST | X |
Notes:
- This call is not associated with a PCB.
- The alternate PCB used by this call must be modifiable.