DFS4608E COULD NOT UNDO MOLC FOR DEDB ALTER DEDB=ddddddd RC=rrrrrrrr RSN=aaaaaaaa MODULE=bbbbbbbb

Explanation

During IMS restart, IMS detected that the DEDB Alter utility was running when IMS abnormally terminated. IMS detected that the STAGING member for the DEDB=dddddddd had been copied into the active library at the time of the IMS failure. The attempt to restore the ACTIVE ACBLIB member failed. The RC is set by DBFMOLS0 during the UNDO MOLC call. The RSN code identifies from where in the code the message was issued.

System action

Emergency restart continues.

System programmer response

Verify that the DEDB member in the ACTIVE ACBLIB is from the STAGING member. If it is, the DEDB member in the ACTIVE ACBLIB must be manually restored from the backup ACBLIB of active members.

Module

DBFEDA00