DFS3265I xxxxxx ERROR DURING WADS PROCESSING


or

xxxxxx ERROR IN WADS DD - ddname

Explanation

The specified write-ahead data sets (WADS) error was encountered while the Log Recovery Utility was performing in CLS or DUP mode with the CLOSE option. The values for xxxxxx can be:
OPEN
An error occurred while opening the WADS.
READ
An error occurred while reading the WADS.
DEVICE TYPE
The device type of the data set specified as a WADS is not DASD.
SEQUENCE #
Data required to properly close the online log data sets (OLDS) is missing from WADS.
CLOSE
An error occurred while closing the WADS.
TRKCALC
An error occurred in the MVS TRKCALC function.
LOGIC
An internal logic error was detected by the WADS read module (DFSFDLW0).
VERIFY
An error was found in the WADS DD statement (DFSWADS0).
MISSING RCD
A sequence of WADS records had fewer records than it should.

System action

The Log Recovery utility, DFSULTR0, terminates with abend 3265.