DFS2067I BEGIN-END BRACKET ERROR NODE x (USER y).

Explanation

IMS detected an error while processing an output message. The message to be sent indicates begin bracket, but the node is in a "NOBB" (cannot begin an output bracket) shutdown state. The requested message could not be sent.

The "NOBB" shutdown state is the result of OHS requesting a symmetric shutdown or a /QUIESCE NODE x (USER y) command.

System action

Session termination was forced for NODE x or USER y. An IMS trace log record (X'67'), containing pertinent information, was produced with an ID of CVCT.

Operator response

See Programmer response.

Programmer response

The session can be restarted to reset the shutdown state if additional input or output is required. Session initiation can be attempted using an IMS /OPNDST command for NODE x or USER y. The session can also be requested or initiated by NODE x or USER y.

Problem determination

1, 5, 6, 12, 14, 25