DFS4464E FAILURE OPENING THE ACBGEN CATALOG WORK FILE. (DDNAME ACBCATWK) OPEN RC = rc
Explanation
The IMS Catalog Populate utility (DFS3PU00) received return code rc from an OPEN macro instruction when attempting to open the ACB generation work file that is referred to by the ACBCATWK DD statement.
In
the message text:
- rc
- The return code received by the DFS3PU00 utility from the z/OS® DFSMS OPEN macro instruction.
System action
The utility ended with return code 12. The catalog was not updated.
Programmer response
Ensure that the DD statement with the ddname ACBCATWK refers to the sequential file created during ACB generation. The work file has a list of the ACB library members from which the catalog records are created. No DCB information needs to be provided on the DD statement.