DFS4172I FDR FOR (imsid) ACTIVE SYSTEM NOT FOUND OR IN FAILED STATUS
Explanation
The imsid of the IMS system was verified by the Fast DB Recovery region. However, either the imsid was not identified to IRLM, or the identified system has a failed status.
System action
The Fast DB Recovery region waits for the active system to join the group.
Operator response
Use the IRLM MODIFY command (F irlmproc,STATUS) to display the status of the identified IMS system. To ensure that the IMS system is active, check that the imsid specified in the IMSID parameter of the EXEC statement is identical to the imsid of the active system. Correct any errors and restart, or let ARM restart, the IMS active system.
If the IMS system is XRF capable, RSENAME is used for the identifier instead of imsid, which causes this message and an abend.