DFS2645I UTILITY STOP CI RBA xxxxxxxx yyyyyyyy


or

UTILITY STOP SEG TS clock value

or

UTILITY STOP USEDCI xxxxxxxx yyyyyyyy

or

UTILITY STOP io/ci# xxxxxxxx yyyyyyyy

or

UTILITY STOP SEGEND xxxxxxxx yyyyyyyy

Explanation

The sequential dependent utility stopped processing at time stamp xxxxxxxx yyyyyyyy. The reason the utility stopped processing is based on one of the following:

SCAN
  • UTILITY STOP CI RBA is the cycle count and control interval (CI) boundary where the SCAN stopped.
  • UTILITY STOP SEG TS is the time stamp associated with the SCAN stoppage.
  • UTILITY STOP SEGEND is the cycle count and RBA of the last SDEP (non-dummy) data segment read by the SCAN.
  • UTILITY STOP USEDCI is the cycle count and CI boundary that SCAN encountered as not marked full. If QUITCI is not specified, SCAN does not go past this CI.
  • UTILITY STOP io/ci# is the number of I/O operations performed and the number of CIs processed.
DELETE
  • UTILITY STOP CE RBA is the cycle count and RBA of the CI boundary where the DELETE stopped.
  • UTILITY STOP SEG TS is the time stamp associated with the DELETE stop time plus 3 microseconds.
  • UTILITY STOP io/ci# is the number of I/O operations performed and the number of CIs processed.

System action

The utility completes normally.

Programmer response

No action is required.

Module

DBFUMPR0