DFS2404A AN ERROR WAS ENCOUNTERED WHEN ACCESSING THE COUPLING FACILITY STRUCTURE xxxxxxxxxxxxxxxx RSN yyy

Explanation

A batch job encountered an error while attempting to access a coupling facility structure for structure name xxxxxxxxxxxxxxxx for a read and register operation or a write operation.

The following list describes the reason codes and provides recommended actions.

Code (hex)
  Meaning
238
A loss of connection to the coupling facility occurred during a read and register operation with no data transfer. See the system console for additional connection error messages. Resolve the coupling facility failure for the batch to continue.
239
A coupling facility structure failure occurred during a read and register operation with no data transfer. See the system console for additional structure failure messages. Resolve the coupling facility failure for the batch to continue.
241
The read and register operation was purged with no data transfer. Determine why the connector failed. Resolve the coupling facility failure for the batch to continue.
242
The read and register operation failed for a reason other than loss of connection, structure failure, and operation being purged with no data transfer. Resolve the coupling facility failure for the batch to continue.
243
The structure was full during a read and register operation with a data transfer. See the system console for additional error messages. Resolve the coupling facility failure for the batch to continue.
244
The read and register operation with data transfer failed for a reason other than the structure was full. See the system console for additional error messages. Resolve the coupling facility failure for the batch to continue.
245
The structure was full during a write operation. See the system console for additional error messages. Resolve the coupling facility failure for the batch to continue.
246
The write operation failed due to an environmental error for other reason than structure being full. See the system console for additional error messages. Resolve the coupling facility failure for the batch to continue.
247
The cross invalidation operation failed due to an environment error. See the system console for additional error messages. Resolve the coupling facility failure for the batch to continue.

System action

The batch application program waits for the coupling facility to be available to continue processing. The system log contains possible explanations of coupling facility operation failure.

System programmer response

Resolve the coupling facility failure for the batch application to continue processing.

Problem determination

1, 2, 3, 6

Module

DFSDMAW0