DFS1710A AREA areaname TRIED TO CONNECT TO STR: structure_name WRITE ERROR EEQE RBA 0 FOUND- RECOVERY NEEDED.
Explanation
A new structure was being connect to this area. There were I/O toleration data on the last structure connected as indicated by the write error EEQE at RBA 0. Those data were lost and the area must to be recovered.
In the message text:
- areaname
- The name of the area being connected
- structure_name
- The name of the new structure
System action
After disconnecting from the new structure, the area is stopped and mark recovery needed.
Programmer response
Ensure the area data set (ADS) is marked unavailable.
Run the database recovery utility to recover the lost data and delete the EEQE.