DFS9112W xxx yyyyyyyy IS NOT PRESENT IN THE zzzzzzz DIRECTORY. | xxx yyyyyyyy IS NOT PRESENT IN THE ACBLIB DATA SET.

Explanation

An object has a non-zero ACTIVE or PENDING timestamp and is not found in the ACTIVE or STAGING directory dataset.

If IMS management of ACBs is enabled, the version of the message text that mentions the directory is displayed and indicates that a resource has a non-zero ACTIVE or PENDING timestamp and is not found in the ACTIVE or STAGING directory dataset.

If IMS management of ACBs is not enabled, the version of the message text that mentions the ACBLIB data set is displayed and indicates that the resource listed is not found in the ACBLIB data set.

In the message text:
xxx
The resource type, either DBD or PSB.
yyyyyyyy
The object name.
zzzzzzz
The directory type, either ACTIVE or STAGING.

System action

The Catalog Maintenance utility issues this warning message and continues to process other objects.

Programmer response

If the object is determined to be necessary in the directory, add it and resubmit the Catalog Maintenance utility job.

Module

DFS3CM00