DFS3754A UTILITY=utility-name TERMINATED BECAUSE AREA=areaname STOPPED
or
Explanation
In the first form of this message, the named Fast Path utility being used terminated because the named area stopped. In the second form, utility-name skipped processing the area because the area is stopped.
If the area is quiesced, the second form of this message is issued and the utility-name skips processing the area.
System action
In the first form of this message, the Fast Path utility being used terminates. In the second form, the Fast Path utility continues with the next area in the input stream.
Operator response
Restart the area using a /START AREA or UPDATE AREA START(ACCESS) command, and rerun the named utility.