DFS3279I INCOMPLETE DEDB LOG CHAIN MAY REMAIN IN PREVIOUS LOG DATA SET
Explanation
The Log Recovery utility terminated successfully. Because no sync point
complete
log record (X'5937' or X'37') was found, an incomplete
DEDB might remain in the log record chain in the previous log data set (OLDS
or SLDS).
System action
The Log Recovery utility terminates with return code X'04'
Programmer response
If the previous log is OLDS, rerun the job in CLS mode and include the previous OLDS as a concatenated data set with the current OLDS. Also, specify PSBLIST=YES and DBRC=NO as EXEC parameters.
If the previous OLDS was already archived into an SLDS, run a Log Recovery utility job in DUP mode and specify the SLDS as an input data set. Also, specify PSBLIST=YES and DBRC=YES as EXEC parameters.
Note: If the closed OLDS is the only OLDS used since cold start,
ignore this message.