DFS3206 REMOTE LOGICAL LINK NOT ASSIGNED LINK nnn

Explanation

The partner ID specified in the bind identifies a logical link belonging to a different physical link at the remote IMS.

See also message DFS3213I, reason code 04 and 08.

System action

IMS prevents the link from starting.

Operator response

Use the /DISPLAY ASMT command at the remote IMS to display the logical-to-physical link assignments, and correct them using the /MSASSIGN MSLINK or UPDATE MSLINK command if in error. Notify the system programmer of the problem.

System programmer response

An IMS system definition is appropriate if the sysdef is incorrect.

Problem determination

10