DFS2957W OLCSTAT DATA SET DYNAMIC ALLOCATION ENCOUNTERED AN ERROR; RETRYING THE ALLOCATION
Explanation
Your attempt to warm start or emergency restart
this IMS system is in a wait
state during dynamic allocation of the OLCSTAT data set. This wait
occurs because the OLCSTAT data set is being held by another user.
The IMS system tries the dynamic
allocation of the data set again and continues trying until one of
the following occurs:
- The OLCSTAT data set is no longer in use by the other user.
- The maximum number of retry attempts has been reached.
System action
If the OLCSTAT data set is freed by the user holding it, processing continues.
If the maximum number of attempts has been reached, IMS terminates abnormally with 2801, subcode 1, accompanied by message DFS2848E.
Operator response
If IMS terminates with and abend code of 2801, subcode 1, determine the user that has a hold on the OLCSTAT data set. Free the data set and start IMS again.Module
DFSOLCS0