DFS2065I RESYNCHRONIZATION NOT POSSIBLE NODE x (USER y).
Explanation
Message resynchronization was required based on the previous session termination with NODE x or USER y. However, the Get Unique call from the shared queues has failed.
System action
The attempt to establish a session with NODEx or USER y has been terminated. An IMS trace log record (X'67') containing pertinent information was produced with an ID of CVCT.
Operator response
See Programmer response.Programmer response
Reinitialize NODE x or USER y to the appropriate restart point, or override the IMS resynchronization system definition option through the IMS /CHANGE command.
When the problem is corrected or overridden, session initiation can be attempted again using an IMS /OPNDST command for NODE x or USER y. The session can also be requested or initiated by NODE x or USER y.