DFS2041 A PERMANENT ERROR ENCOUNTERED NODE x

Explanation

The SENSE information returned on a VTAM® SEND/RECEIVE indicated NODE x was inoperable. The probable causes for this problem are:
  • A VTAM logical unit status was received, or an exception response to a SEND command was received with a SENSE command, indicating a permanent error (set by NODE x).
  • Unsupported major or minor SENSE fields or the user SENSE indicated a component ID greater than 4.
  • A hardware malfunction.

System action

The session established for NODE x is terminated. An IMS log record with an ID of CVCT containing pertinent information was produced.

Programmer response

When the problem is corrected, the session can be reestablished by a NODE x, or an IMS /OPNDST command.

Problem determination

1, 5, 6, 11, 14