DFS1282E UNABLE TO CREATE OR USE TPIPE=tpipe FOR MEMBER=member
Explanation
An OTMA client requested IMS to use an existing Tpipe or create a new
Tpipe. One of two errors occurred:
- IMS was unable to allocate storage to create a new Tpipe.
- The Synchronized Tpipe flag in the processing flag of the OTMA message-control-information prefix was set incorrectly on or off for an existing tpipe.
After a tpipe is created for an input or output OTMA message, the Synchronized Tpipe setting for the Tpipe cannot be changed for the subsequent input or output OTMA message.
In the message text:
- tpipe
- Identifies the 8-byte transaction pipe name
- member
- Identifies the 16-byte client name
System action
IMS responds to the original OTMA message with a NACK message.
Programmer response
Ensure the IMS system has enough available storage. Also, check the Synchronized Tpipe flag in the processing flag of the OTMA message-control-information prefix.
Module
DFSYMEM0