DFS1282E UNABLE TO CREATE OR USE TPIPE=tpipe FOR MEMBER=member

Explanation

An OTMA client requested IMS to use an existing Tpipe or create a new Tpipe. One of two errors occurred:
  • IMS was unable to allocate storage to create a new Tpipe.
  • The Synchronized Tpipe flag in the processing flag of the OTMA message-control-information prefix was set incorrectly on or off for an existing tpipe.

After a tpipe is created for an input or output OTMA message, the Synchronized Tpipe setting for the Tpipe cannot be changed for the subsequent input or output OTMA message.

In the message text:
tpipe
Identifies the 8-byte transaction pipe name
member
Identifies the 16-byte client name

System action

IMS responds to the original OTMA message with a NACK message.

Programmer response

Ensure the IMS system has enough available storage. Also, check the Synchronized Tpipe flag in the processing flag of the OTMA message-control-information prefix.

Module

DFSYMEM0