- DatastoreName
-
The name of the IMS data store to access.
When using type-4 connectivity, the DatastoreName property must match
either the name of the data store defined to ODBM or be blank. The data store name is defined
in the ODBM CSLDCxxx PROCLIB member using either the DATASTORE(NAME=name)
or DATASTORE(NAME=name, ALIAS(NAME=aliasname))
parameter. If an alias is specified, you must specify the aliasname as the
value of the datastoreName property. If the
DatastoreName value is left blank (or not supplied), IMS Connect connects to any available instance of ODBM as it is assumed
that data sharing is enabled between all datastores defined to ODBM.
When using type-2 connectivity, set the DatastoreName property to the
IMS subsystem alias. This is not required to be set for
the Java™ Dependent Region run time.
- DatabaseName
-
The location of the database metadata representing the target IMS database.
The DatabaseName property can be specified in one of two ways,
depending on whether the metadata is stored in the IMS
catalog or as a static metadata class generated by the IMS Enterprise
Suite Explorer for Development.
If your IMS system uses the IMS catalog, the DatabaseName property is the name
of the PSB that your application uses to access the target IMS database.
If you are using the IMS Explorer for
Development,
the databaseName property is the fully qualified name of the Java metadata class generated by the IMS Explorer for
Development. The URL must be prefixed with
class:// (for example, class://com.foo.BMP255DatabaseView).
In a J2C Connection Factory environment, the DatabaseName property can
be overridden for an individual connection without affecting the default value specified for
the resource adapter.
- MetadataURL
-
The location of the database metadata representing the target IMS database.
This property is deprecated. Use
DatabaseName instead.
The MetadataURL property is the fully qualified name of the Java metadata class generated by the IMS Enterprise
Suite Explorer for Development. The URL must be prefixed
with class:// (for example,
class://com.foo.BMP255DatabaseView).
In a J2C Connection Factory environment, the MetadataURL property can
be overridden for an individual connection without affecting the default value specified for
the resource adapter.
- PortNumber
-
The TCP/IP server port number to be used to communicate with IMS Connect. The port number is defined using the DRDAPORT parameter on the ODACCESS
statement in the IMS Connect configuration PROCLIB
member. The default port number is 8888. Do not set this property when using type-2
connectivity.
- DatastoreServer
-
The name or IP address of the data store server (IMS
Connect). You can provide either the host name (for example, dev123.svl.ibm.com) or the IP
address (for example, 192.166.0.2). Do not set this property when using type-2
connectivity.
- DriverType
-
The type of driver connectivity to use (value must be
IMSDataSource.DRIVER_TYPE_4 for type-4 connectivity or
IMSDataSource.DRIVER_TYPE_2 for type-2 connectivity).
- user
-
The user name for the connection to IMS Connect
provided by your RACF® administrator. Do not set this
property when using type-2 connectivity.
- password
-
The password for the connection to IMS Connect provided
by your RACF administrator. Do not set this property
when using type-2 connectivity.
- allMetadata
-
Optional. When this property is set to true, the DatabaseMetadata interface
returns information for all resources in the IMS catalog. When the property is set to
false, the DatabaseMetadata interface returns information for the allocated
PSB. The default value for this property is false.
- initStatusGroup
- Optional. When a connection is made and the PSB is allocated, this property will indicate that
the driver should automatically issue an
INIT STATUS GROUPA or INIT STATUS
GROUPB if a value of 'A' or 'B' is provided. The default will not issue an INIT STATUS
GROUP call.
- sslConnection
-
Optional. Indicates if this connection uses Secure Sockets Layer (SSL) for data encryption.
Set this property to true
to enable SSL, or to false
otherwise. Do not set this
property when using type-2 connectivity.
-
- sslKeyStoreType
-
Optional. Specifies the format of the file that contains cryptographic objects needed to
establish a secure socket connection. The valid values are JKS
and PKCS12
.
This value is only used when sslConnection is set to true
and
sslKeyStoreType is not specified. The
sslKeyStoreType parameter defaults to JKS
.
- sslSecureSocketProtocol
-
Optional. Specifies the cryptographic communication protocol for the new connection.
Specify a protocol that is supported by the server and provides the highest level of
security. The valid values are SSL
, SSLv3
, TLSv1.1
, and
TLSv1.2
. This value is only used when sslConnection is set to
true
. If sslConnection is set to true
and
sslSecureSocketProtocol is not specified, a default protocol will be
determined at runtime by the JRE and the server.
- sslTrustStoreLocation
-
Optional. Specifies the location of the cryptographic trust store file for the new
connection. This value is only used when sslConnection is set to
true.
- sslTrustStorePassword
-
Optional. Specifies the password to access the cryptographic trust store file. This value
is only used when sslConnection is set to true.
- sslKeyStoreLocation
-
Optional. Specifies the location of the cryptographic key store file for the new
connection. This value is only used when sslConnection is set to
true.
- sslKeyStorePassword
-
Optional. Specifies the password to access the cryptographic key store file. This value
is only used when sslConnection is set to true.
- loginTimeout
-
Optional. Specifies the number of seconds that the driver waits for a response from the
server before timing out a connection initialization or server request. Set this property to a
non-negative integer for the number of seconds. Set this property to 0 for an infinite timeout
length. Do not set this property when using type-2 connectivity.
- signedCompare
-
Optional. When this property is set to true
, special SSAs are generated to support
ranged queries over signed data types. If the property is set to false
, standard binary
comparisons are performed based on the binary representation of the data type value. Setting
the value to false
can increase performance but might result in incorrect results. The
default value for this property is true
.
- flattenTables
-
Optional. Indicates whether to produce a flattened view of the database tables. A
value of true exposes the sub-elements of a STRUCT or an ARRAY as additional columns of the
table. The default value is false.
IMS Explorer flattens the copybook structures when you import the copybook. Although the
copybook itself remains unchanged in the IMS catalog, the information about the structure of
each table is altered for that particular connection.
The the flattenTables property allows you to query the fields in complex structures
directly. For more information about support for flattening complex structures, see Support for flattening complex structures.
Restriction: The flattenTables connection
property supports static arrays and structures only. Dynamic arrays are not altered.
- t2OutputBufferSize
-
Optional. The size of the output buffer in bytes for the results from a SELECT operation for
a type-2 connection.
The minimum value for t2OutputBufferSize is 500000. If any value less than 500000 is set,
this property value will be adjusted to 500000. There is no maximum bound. The default value
is 1280000.
- treatInvalidDecimalAsNull
-
Optional. Indicates whether to interpret certain Decimal values that appear invalid in Java applications (such as PACKEDDECIMAL and ZONEDDECIMAL
with invalid sign bits) as null. By default, this property is false
, and a conversion
exception is thrown when the Java applications are
processing invalid values.
- removeInvalidCaseFields
-
Optional. If you use SELECT * to access a map case, the JDBC Universal Driver returns the
set of all map case segment fields. When this property is set to true, the results contain
only map case fields that satisfy a WHERE clause with a DEPENDINGON field condition. To learn
more, see Using the removeInvalidCaseFields property.