DFS677I PERMANENT I/O ERROR ON JOB/LINK/SVCLIB FOR FOLLOWING MODULES:

Explanation

Module preload encountered an I/O error when scanning the PDS directories for STEPLIB, JOBLIB, SYS1.LINKLIB, or SYS1.SVCLIB. The modules for which it was scanning are listed following this message.

System action

IMS terminates abnormally with an abend 0718.

Operator response

Contact your IMS system programmer for assistance.

Programmer response

If you decide this is a permanent condition, follow your PDS recovery procedure.

Problem determination

1, 4, 8, 36

Module

DFSPLPP0