DFS0596W READ FAILED FOR DDNAME xxxxxxxx MEMBER= yyyyyyyy
Explanation
The READ failed for member yyyyyyyy from the DDNAME xxxxxxxx data set. This problem can prevent IMS from acquiring information required for initialization.
The
DDNAME xxxxxxxx data set is not valid for processing.
This problem can prevent IMS from acquiring information required
for initialization. This message is preceded by message DFS0596W, READ
FAILED
, which provides the member name for the attempted
READ.
In the message:
- xxxxxxxx
- Data set name
- yyyyyyyy
- Member
- variable text
- The operating system SYNADAF macro instruction supplies the text of this message.
System action
IMS might terminate with abend 0015 if the member is required by IMS. IMS terminates with abend 1012 if the member is DBFMSDBn.
Operator response
(master terminal) If IMS does not abend, determine if member yyyyyyyy is necessary for your installation.Programmer response
For a required member, make sure that the correct suffix was specified, and member yyyyyyyy is valid. Attempt to rebuild the member in a different location in the data set.