DFS4614E DEDB ALTER REQUIRES A 2 STAGE RANDOMIZER
Explanation
The DEDB Alter utility detected that the DEDB database to be altered uses a one-stage randomizer and includes more than one area. The DEDB Alter utility only supports DEDB databases that use a two-stage randomizer or that use a one-stage randomizer and have only a single area.
System action
The DEDB Alter utility terminates without completing the requested function.
System programmer response
Convert the DEDB database to use a 2-stage randomizer:
- If the randomizer is a one-stage randomizer, and the DEDB has more than one area, unload and reload the DEDB database using a two-stage randomizer. Then perform an online change to change the randomizer from a one-stage randomizer to a two-stage randomizer.
- If the randomizer is a one-stage randomizer that behaves like a two-stage randomizer, perform an online change to change the randomizer from a one-stage randomizer to a two-stage randomizer.