DFS4601I RSN=00 DEDB dedbname SERIALIZATION PROCESS STARTED


or

RSN=01 DEDB dedbname SERIALIZATION PROCESS ENDED SUCCESSFULLY

or

RSN=03 DEDB dedbname SERIALIZATION FAILED – THREAD yyyyyyyy UPDATED THE DEDB BUT WAS NOT SERIALIZED

or

RSN=04 DEDB dedbname SERIALIZATION FAILED – THREAD yyyyyyyy WITH UPDATE INTENT FOR THE DEDB WAS NOT SERIALIZED

or

RSN=06 DEDB dedbname SERIALIZATION TIMED OUT WHILE ATTEMPTING TO SERIALIZE THE DEDB

or

RSN=07 DEDB dedbname SERIALIZATION TIMED OUT – RETRY STARTING

or

RSN=08 DEDB dedbname SERIALIZATION TIMED OUT – RETRY STARTING

or

RSN=09 DEDB dedbname SERIALIZATION TIMED OUT – RETRY STARTING

or

RSN=0A DEDB dedbname SERIALIZATION TIMED OUT – RETRY STARTING

or

RSN=0B DEDB dedbname SERIALIZATION TIMED OUT – RETRY STARTING
or

RSN=0C DEDB dedbname SERIALIZATION TIMED OUT WHILE ATTEMPTING TO SERIALIZE THE DEDB

Explanation

During the DEDB Alter process, the DEDB database needed to be serialized with application threads.
  • If the process completed successfully, RSN=01 will be the last message in the stream.
  • If the serialization process fails, the last message in the stream will be DFS4601E RSN=02 with a preceding DFS4601I message to explain the failure.
Reason code
Meaning
RSN00
The DEDB serialization process started for DEDB dedbname.
RSN01
The DEDB serialization process ended successfully. The area was serialized by the DEDB Alter utility.
RSN03
The DEDB serialization process failed. Thread yyyyyyyy updated DEDB dedbname, but DEDB dedbname was not correctly serialized.
RSN04
The area serialization process failed. Thread yyyyyyyy was not involved with serializing DEDB dedbname, but the task was unable to determine whether this was acceptable.
RSN06, RSN0C
The DEDB serialization process timed out while attempting to serialize the area in exclusive mode.
RSN07, RSN08, RSN09, RSN0A, RSN0B
The DEDB serialization process timed out while attempting to serialize the DEDB in exclusive mode. Another attempt to serialize the DEDB will be made because RETRY YES or RETRY retry_value was specified as a DEDB Alter utility input option.

System action

If the DEDB serialization is successful, the DEDB Alter utility continues processing. If the DEDB serialization is unsuccessful, the DEDB Alter utility terminates processing without performing the requested DEDB Alter function.

Module

DBFDAQA0