DFS3999W A STOP TIME WAS SUPPLIED WHICH EXCEEDS
THE TIME RANGE IN THE LOG.
STOP TIME: stop time TIME
ON LAST RECORD: record time
Explanation
A value for the STOPTIME keyword was supplied in the CONTROL data set. The stop time value exceeded the latest time stamp on the last processed log record. This situation might be valid; however, it might indicate that the concatenation of log data sets in DD SYSUT1 is incomplete.
System action
The Create RDDS from Log Records utility (DFSURCL0) continues processing. It terminates successfully with a return code 4.
Programmer response
Ensure that all of the log data sets you want are included in the SYSUT1 DD concatenation.