DFS302A INVALID OR MISSING FUNCTION ff SPECIFIED ON REQUEST nnnn

Explanation

A utility control statement with an invalid or missing control function code was detected. The ff is either omitted or, if present, was not a valid 2-character codes. For the valid codes, see information about the Utility Control Facility. The nnnn is the control request number.

System action

Processing is terminated with a nonzero return code.

Programmer response

Correct the control statement, depending on the utility program being executed, and resubmit the job. See abend code 302.

Problem determination

2, 3, 8, 35. Also, if running under the Utility Control Facility, rerun the job with a FUNCTION=OP,MSGNUM=302 control statement in the DFSYSIN data set. You must supply a SYSUDUMP DD statement in this step. PSB pool should be much larger than the CSA PSB pool.

Module

DFSUCP40