DFS292I INVALID RANGE SPECIFICATION

Explanation

The following are possible causes of this message:
  • Range parameters were specified with a keyword that does not support range parameters.
  • The second member of the range specification was not larger than the first.
  • One of the nodes specified is not in the system.
  • Both of the nodes specified are dynamic.

System action

The command is ignored.

Operator response

Reenter the command correctly.

Range specifications apply only to the keywords LINE, LINK, NODE, and PTERM. Range specifications for the NODE keyword apply only to static nodes. Both members of the range specification must exist and must be defined through system definition.

For dynamic terminals or users, generic parameter support replaces range specifications. A generic parameter contains one or more special characters, *, or '. The asterisk indicates that at least one character might replace it, creating a valid resource name. For example, /DISPLAY NODE *SLU6* displays nodes which contain the character string SLU6.

Module

DFSICL30