HPCSYSIN DD parameters
JCL parameters that control the operation of IMS HP Change Accumulation Utility are read from the HPCSYSIN DD statement in all modes.
However, many parameters are processed in specific environments. In addition, command syntax is validated only for the extended batch environment.
The following table lists the parameters that can be used in the HPCSYSIN DD statement to control the operation of IMS HP Change Accumulation Utility.
Parameter | Extended
batch |
Two-step
batch step 1 |
Two-step
batch step 2 |
ISPF/UI
(Note 1) |
---|---|---|---|---|
CA.ALLSPILL | Yes | N/A | Yes | Yes |
CA.DATACLAS | Yes | N/A | N/A | Note 2 |
CA.MGMTCLAS | Yes | N/A | N/A | Note 2 |
CA.PREFIX | Yes | N/A | N/A | Note 2 |
CA.PRIMARY | Yes | N/A | N/A | Note 2 |
CA.SECONDARY | Yes | N/A | N/A | Note 2 |
CA.SPACE | Yes | N/A | N/A | Note 2 |
CA.START | Yes | N/A | Yes | Yes |
CA.STORCLAS | Yes | N/A | N/A | Note 2 |
CA.UNIT | Yes | N/A | N/A | Note 2 |
CA.UNIT COUNT | Yes | N/A | N/A | Note 2 |
CA2PITCA DSN | Yes | N/A | Yes | Yes |
CA2PITCA UNIT | Yes | N/A | N/A | N/A |
|
||||
DSP0025I RC | Yes | N/A | N/A | N/A |
DYNMSG | Yes | N/A | Yes | Yes |
|
||||
FP.DATACLAS | Yes | N/A | N/A | Note 2 |
FP.MGMTCLAS | Yes | N/A | N/A | Note 2 |
FP.NOEEQES | Yes | N/A | Yes | Yes |
FP.NOSPILL | Yes | N/A | Yes | Yes |
FP.PREFIX | Yes | N/A | N/A | Note 2 |
FP.PRIMARY | Yes | N/A | N/A | Note 2 |
FP.SECONDARY | Yes | N/A | N/A | Note 2 |
FP.SPACE | Yes | N/A | N/A | Note 2 |
FP.STORCLAS | Yes | N/A | N/A | Note 2 |
FP.UNIT | Yes | N/A | N/A | Note 2 |
FP.UNIT COUNT | Yes | N/A | N/A | Note 2 |
|
||||
GEN.GENJCL | Yes | N/A | N/A | Note 2 |
GEN.GRPNAME | Yes | N/A | N/A | Note 2 |
GEN.LIST | Yes | Note 4 | N/A | Note 3 |
GEN.RETRY | Yes | N/A | N/A | N/A |
GEN.STOP | Yes | N/A | Yes | N/A |
GEN.WARN | Yes | N/A | N/A | N/A |
HALDB | Yes | N/A | Yes | Yes |
ID | Yes | Note 4 | N/A | Note 2 |
INPUT BUFFERS | Yes | N/A | Yes | Yes |
JOB | Yes | N/A | N/A | Note 2 |
LIST/NOLIST | Yes | N/A | N/A | N/A |
LOG TIME | Yes | N/A | Yes | Yes |
MAXIMUM LOGS | Yes | Note 4 | N/A | N/A |
MAXLOGS RC | Yes | Note 4 | N/A | N/A |
MEMLIMIT | Yes | N/A | Yes | Yes |
OUTPUT BUFFERS | Yes | N/A | Yes | Yes |
PARALLEL LOGS | Yes | N/A | N/A | Note 2 |
PDS | Yes | N/A | N/A | N/A |
PROCEDURE NAME | Yes | Note 4 | N/A | Note 2 |
QUEUE BUFFERS | Yes | N/A | Yes | Yes |
|
||||
RPT.COLUMNS | Yes | N/A | Yes | Yes |
RPT.DATE | Yes | N/A | Yes | Yes |
RPT.ORDER | Yes | N/A | Yes | Yes |
RPT.SUMMARY | Yes | N/A | Yes | Yes |
|
||||
SECLOG.UNIT | Yes | Yes | N/A | Yes |
SECLOG.VOLSER | Yes | Yes | N/A | Yes |
SELECT LOGS | Yes | N/A | Yes | Note 2 |
|
||||
SORT.DYNALLOC COUNT | Yes | N/A | N/A | Note 2 |
SORT.FILSZ | Yes | N/A | N/A | Note 2 |
SORT.HIPRMAX | Yes | N/A | N/A | Note 2 |
SORT.MAINSIZE | Yes | N/A | N/A | Note 2 |
SORT.MSGDDN | Yes | N/A | N/A | Note 2 |
SORT.SMF | Yes | N/A | N/A | Note 2 |
|
||||
SPILL BLKSIZE | Yes | N/A | N/A | Note 2 |
SUM.FILES | Yes | N/A | Yes | Yes |
SUM.REPORT CLASS | Yes | N/A | Yes | Yes |
SUM.SORT | Yes | N/A | Yes | Yes |
STC NAME | Yes | Note 4 | N/A | Note 2 |
UNIT | Yes | N/A | Yes | N/A |
USE CATALOG | Yes | N/A | Yes | Yes |
WAIT FOR UNIT | Yes | Yes | Yes | Yes |
<<TRACE>>Note 1 | Yes | Yes | Yes | Yes |
<<DEBUG>> | Yes | Yes | Yes | Yes |
Notes:
- HPCSYSIN DD is allocated when the IMS HP Change
Accumulation Utility ISPF user interface starts.
The data set is allocated to HPCSYSIN at setup option 9; JCL DD control is used in the IMS HP Change Accumulation Utility driver step that is submitted by the RUN command.
- These values are entered as ISPF values on setup panels.
- The DBRC list is displayed if RC>0 is returned.
- This value is entered in the EXEC PARM, not as a command.