Setting index rebuild options
If you specify Y in the Execute Index Rebuild field, you can also specify Y in the Edit Options field to further customize Index Rebuild options.
About this task
Procedure
- On the Recovery Options panel, specify Y in the Edit Options field next to Execute Index Rebuild, and press Enter.
-
On the Index Rebuild Utility Options panel, you can specify the following
information:
Figure 1. Index Rebuild Utility Options panel IMS RE V2R2 ------- Index Rebuild Utility Options ------- 2021/04/17 12:43:0 Option ===> ------------------------------------------------------------------------------- Creator: ****** Name: ****** SSID: IDA Share Option: U (Upd,View,No) Description: TEST ------------------------------------------------------------------------------- Enter the options for the index rebuild utility: FF GENJCL member name ==> BSYIIB Use FF for HALDB ==> Y (Yes/No) HALDB GENJCL member name ==> BSYPREC0 FP GENJCL member name ==> BSYFPSI Rebuild even if recoverable ==> Y (Yes/No) Rebuild HALDB on recover to current ==> Y (Yes/No) Delete/Define PDS DSN ==> IMS.DELDEF Datasets for GENJCL ==> TSMXD.BSY.DEMO.JCLPDS ==> IMSQA.BSY220.DATA.JCLPDS ==> ==> ==> Enter END command to return to the previous screen
- FF GENJCL member name
- Specify the skeleton member name to be used for the index rebuild utility when rebuilding indexes associated with full function and HALDB indexes. If the Use FF for HALDB option is set to Y, then this member is also used for HALDB ILDS and PINDEX processing.
- Use FF for HALDB
- Specify Y if you want to use the FF GENJCL skeleton member for processing HALDB ILDS and PINDEX; specify N if you do not want to do this.
- HALDB GENJCL member name
- Specify the skeleton member name to be used for processing HALDB ILDS or PINDEX. If the Use FF for HALDB option is set to Y, then you must leave this field blank.
- FP GENJCL member name
- Specify the skeleton member name to be used for Fast Path secondary indexes. If you do not want FP secondary indexes processed, leave this field blank.
- Rebuild even if recoverable
- Specify whether you always want indexes rebuilt after the recovery of the target database. Specify Y to always rebuilt indexes. Specify N to rebuild indexes only if they cannot be recovered.
- Rebuild HALDB on recover to current
- Specify whether you want the HALDB ILDS and PINDEX rebuilt even when the partition is being recovered to current. Usually, the ILDS and PINDEX do not need to be rebuilt in this situation. Specify Y to rebuild the HALDB ILDS and PINDEX on recovery to current. Specify N to rebuild the HALDB ILDS and PINDEX only when indicated.
- Delete/Define PDS DSN
- Specify the name of a PDS data set that contains IDCAMS statements. These statements are used to
delete and redefine the data sets being recovered before running the recovery utility.
Leave this field blank if you do not want IMS Recovery Expert to build the steps to delete and define indexes prior to a rebuild.
- Datasets for GENJCL
- Displays the concatenation of data sets for GENJCL member selection.
- Press Enter, or specify END on the Option line to return to the Recovery Options panel, or specify CAN to cancel.